Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.197
Filtrar
1.
Medicina (Kaunas) ; 60(3)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38541197

RESUMO

Background and Objectives: This study examined how a history of thyroid surgery impacts the precision of cricothyroid membrane (CTM) identification through palpation (validated by ultrasound) in female patients visiting the operating room for surgeries unrelated to neck procedures. Materials and Methods: This prospective observational cohort study enrolled adult female patients undergoing elective non-neck surgery, dividing them into control (no thyroid surgery history; n = 40) and experimental (with thyroid surgery history; n = 40) groups. CTM identification was performed by palpation and confirmed via ultrasound. Results: There were no significant differences between two groups in the demographic characteristics of the patients. The success rate and accuracy of CTM identification through palpation were significantly higher in the control group compared to the experimental group (90% vs. 42.5%, respectively; p < 0.001). For female patients with a history of thyroid surgery, the sensitivity of successful CTM palpation was 42.5%, and the specificity was 10%. These figures are based on the calculated true positives (17), false positives (36), true negatives (4), and false negatives (23). Conclusions: Thyroid surgery history in female patients may hinder the accurate palpation-based identification of the CTM, suggesting a need for enhanced clinical practices and considerations during airway management training.


Assuntos
Cartilagem Cricoide , Glândula Tireoide , Adulto , Humanos , Feminino , Estudos Prospectivos , Cartilagem Cricoide/diagnóstico por imagem , Cartilagem Cricoide/cirurgia , Cartilagem Tireóidea/cirurgia , Cartilagem Tireóidea/diagnóstico por imagem , Ultrassonografia , Palpação/métodos
2.
Catheter Cardiovasc Interv ; 103(5): 722-730, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38469945

RESUMO

BACKGROUND: The radial first approach in cardiac catheterization is preferred for its benefits in patient comfort and recovery time. Yet, challenges persist due to characteristics like small, deep, calcified, and mobile radial arteries. Utilizing ultrasound before and during procedures can improve success rates. However, the adoption of its use is still limited and subject to debate. AIM: To utilize routine preprocedural ultrasound (US) and compare US guided with palpation guided radial access, focusing on operator efficiency and outcomes. METHODS AND RESULTS: Consenting adult patients undergoing elective radial cardiac catheterization were divided into palpation and US groups. Routine preprocedural assessment of radial artery characteristics was performed using handheld US. Baseline data, US findings, procedural outcomes, and clinical outcomes were compared in 182 participants (91 in each group). US guided radial access had significantly higher first pass success rates (76.92% vs. 49.45%, p 0.0001), fewer number of attempts (1.46 ± 1 vs. 1.99 ± 1.46, p 0.004), and shorter amount of time (93.62 ± 44.04 vs. 120.44 ± 67.1, p 0.002) compared with palpation guidance. The palpation group had significantly higher incidence of spasm (15.38% vs. 3.3%, p 0.0052). Subgroup analysis indicated consistent benefits of US guidance, especially in calcified radial arteries. CONCLUSION: This prospective, nonrandomized, single-center study demonstrated that real-time procedural US improved the operator's time and effort and enhanced patient comfort compared with palpation. US guidance use was particularly favorable in the presence of calcifications observed on baseline preoperative US.


Assuntos
Cateterismo Periférico , Adulto , Humanos , Estudos Prospectivos , Resultado do Tratamento , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Palpação/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Ultrassonografia de Intervenção/métodos
3.
J Oral Rehabil ; 51(5): 879-885, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38240374

RESUMO

BACKGROUND: The Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) protocol recommends a 5 s and 1 kg force dynamic palpation around the lateral condylar pole of the temporomandibular joint. However, the accuracy and precision of the generated force are not known. OBJECTIVE: To assess and compare the force profiles generated from dynamic palpation manually and using a palpometer, based on the forces and time recommendations suggested by the DC/TMD protocol. METHODS: Nineteen healthy adults applied forces of 0.5 kg, 1.0 kg and 2.0 kg on a calibrated force sensor in a circular motion within target times of 2 s and 5 s. Participants used their right index finger for manual palpation and a calibrated palpometer for device-assisted palpation. Ten repetitions of each target force at both target times were applied. Time taken to complete each application was recorded. Repeated measures analysis of variance was used for analysis of accuracy measured as the relative difference between targeted force and actual force values and precision measured as the coefficient of variation (CV) within the 10 repeated measurements. RESULTS: Accuracy was significantly lower (better) and precision higher (lower CV) with the palpometer than with manual palpation (p < .001). There were significant differences in accuracy and precision between the different forces but not palpation times. Most participants could not achieve the target times and tended to be faster, irrespective of the palpation method (p > .063). CONCLUSION: A palpometer is a more accurate and precise palpation method for dynamic force assessment compared to manual palpation; however, it remains difficult to standardize the palpation duration.


Assuntos
Dor Facial , Transtornos da Articulação Temporomandibular , Adulto , Humanos , Medição da Dor/métodos , Dor Facial/diagnóstico , Palpação/métodos , Articulação Temporomandibular , Transtornos da Articulação Temporomandibular/diagnóstico
4.
Ulus Travma Acil Cerrahi Derg ; 29(10): 1075-1080, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37791446

RESUMO

BACKGROUND: Percutaneous tracheostomy (PT) may be required frequently in long-term ventilated intensive care patients. Although the overall risks are low, serious complications may occur, especially in children. Hence, this study aimed to assess physician accuracy in identifying PT insertion sites by digital palpation in children aged between 5 and 13 years. METHODS: Participants were asked to identify the needle entry point (interspace between 2nd and 3rd or 3rd and 4th tracheal rings) for PT using digital palpation. Then, a single operator scanned the neck of each child with a linear high-frequency transducer. An accurate estimation was defined as a mark made between the upper and lower borders of the tracheal rings within the midline. RESULTS: In the study including 104 patients, the PT insertion site was accurately identified with digital palpation in a total of 50.9% of patients, compared with sonographic findings. The time required to determine the PT entry point by USG was longer than the palpation technique (114.7 vs. 43.8 s, P<0.001). The mean distance between the entry points of both methods was 4.53±2.03 mm. The majority of inaccurate assessments (45%) was above the 2nd tracheal ring. The lower the skin-to-air-mucosal interface distance, the higher the success of the PT entry point detection with the digital palpation method. A one-unit increase in body mass index was related to increasing the risk of failure by 1.1 times (P=0.030). CONCLUSION: Significant physician inaccuracy exists in PT insertion sites in children aged between 5 and 13 years, especially as BMI increases. Pre-procedural USG may help identify the landmarks for PT.


Assuntos
Médicos , Traqueostomia , Humanos , Criança , Pré-Escolar , Adolescente , Traqueostomia/efeitos adversos , Traqueostomia/métodos , Índice de Massa Corporal , Palpação/métodos
5.
J Osteopath Med ; 123(11): 531-535, 2023 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-37498573

RESUMO

CONTEXT: Medical students with no previous experience may find it difficult to identify and palpate bony landmarks while learning physical examination skills. In a study of 168 medical schools, 72.6 % have indicated that they are utilizing ultrasound in their curriculum. Although the integration of ultrasound curriculum has become more widespread, the depth of instruction is inconsistent. Ultrasound is not commonly taught in conjunction with palpation of bony landmarks in osteopathic structural examination. OBJECTIVES: The objective of this analysis was to identify whether utilizing ultrasound assistance in teaching palpation of specific thoracic vertebral bony landmarks would improve palpation accuracy in first-year medical students with no previous palpatory experience. METHODS: First-year medical students were given video instructions to palpate and identify a thoracic vertebral transverse process and to mark it with invisible ink. The participants were then taught and instructed to utilize ultrasound to identify the same landmark and mark it with a different color. The accuracy of palpation was measured with digital calipers. RESULTS: A test of the overall hypothesis that participants will show improved accuracy utilizing ultrasound compared with hand palpation was not significant (F=0.76, p>0.05). When separating students into groups according to patient body mass index (BMI), however, there was a trend toward significance (F=2.90, p=0.071) for an interaction effect between patient BMI and the repeated measures variable of palpation/ultrasound. When looking specifically at only those participants working with a normal BMI patient, there was a significant improvement in their accuracy with the use of ultrasound (F=7.92, p=0.017). CONCLUSIONS: The analysis found increased accuracy in bony landmark identification in untrained palpators utilizing ultrasound vs. palpation alone in a normal BMI model, but not in obese or overweight BMI models. This study shows promise to the value that ultrasound may have in medical education, especially with respect to early palpation training and landmark identification.


Assuntos
Palpação , Estudantes de Medicina , Humanos , Palpação/métodos , Ultrassonografia/métodos , Exame Físico , Currículo
7.
Med Intensiva (Engl Ed) ; 47(7): 391-401, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36868961

RESUMO

OBJECTIVE: To compare first attempt success rate for ultrasound-guided (USG) versus direct palpation (DP) for radial, femoral, and dorsalis pedis artery cannulations in adult intensive care unit (ICU) patients. DESIGN: Prospective randomized clinical trial. SETTING: Mixed adult ICU of a University Hospital. PARTICIPANTS: Adult patients (≥18 years) admitted to the ICU requiring invasive arterial pressure monitoring were included. Exclusion criteria were patients with a pre-existing arterial line and cannulated with other than a 20-gauge cannula for radial and dorsalis pedis artery. INTERVENTION: Comparison of arterial cannulation by USG versus palpation technique in radial, femoral and dorsalis pedis arteries. MAIN VARIABLES OF INTEREST: Primary outcome was first attempt success rate, secondary outcomes were assessing time for cannulations, number of attempts, overall success rate, complications, and comparison of two techniques on patients requiring vasopressor. RESULTS: 201 patients were enrolled in study, with 99 randomized to DP group and 102 to USG group. Arteries (radial, dorsalis pedis, femoral) cannulated in both groups were comparable (P = .193). Arterial line was placed on first attempt in 85 (83.3%) in USG group versus 55 (55.6%) in DP group (P = .02). Cannulation time in USG group was significantly shorter compared to DP group. CONCLUSIONS: In our study, USG arterial cannulation, compared to palpatory technique, had a higher success rate at first attempt and a shorter cannulation time. CLINICAL TRIAL REGISTRY OF INDIA NUMBER: CTRI/2020/01/022989.


Assuntos
Cateterismo Periférico , Humanos , Adulto , Cateterismo Periférico/métodos , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos , Artéria Radial/diagnóstico por imagem , Cuidados Críticos , Palpação/métodos
8.
IEEE Rev Biomed Eng ; 16: 514-529, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35439140

RESUMO

Tissue examination by hand remains an essential technique in clinical practice. The effective application depends on skills in sensorimotor coordination, mainly involving haptic, visual, and auditory feedback. The skills clinicians have to learn can be as subtle as regulating finger pressure with breathing, choosing palpation action, monitoring involuntary facial and vocal expressions in response to palpation, and using pain expressions both as a source of information and as a constraint on physical examination. Patient simulators can provide a safe learning platform to novice physicians before trying real patients. This paper reviews state-of-the-art medical simulators for the training for the first time with a consideration of providing multimodal feedback to learn as many manual examination techniques as possible. The study summarizes current advances in tissue examination training devices simulating different medical conditions and providing different types of feedback modalities. Opportunities with the development of pain expression, tissue modeling, actuation, and sensing are also analyzed to support the future design of effective tissue examination simulators.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Retroalimentação Sensorial , Retroalimentação , Palpação/métodos , Simulação por Computador
9.
J Vasc Access ; 24(1): 27-34, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34082593

RESUMO

OBJECTIVES: Palpation technique for femoral artery cannulation can be very difficult, especially in neonates. In this study, we evaluated whether ultrasound-guided cannulation of the femoral artery is superior to palpation technique in neonates undergoing cardiac surgery. METHODS: Forty neonates undergoing cardiac surgery were prospectively randomized into two groups (Ultrasound group and Palpation group). Access time, number of attempts, number of successful cannulations on first attempt, success rate, number of cannulas used, inadvertent access, and complications were compared between the two groups. Cost analyses of the cannulation were performed in two groups. RESULTS: In the ultrasound group, access time for femoral artery cannulation was shorter (6.4 ± 3.0 and 10.2 ± 4.4, p = 0.003) and the number of attempts (1.4 ± 0.6 and 2.3 ± 0.8, p < 0.001) was lower compared to the palpation group. The number of successful cannulations on first-attempt (15 (75%) and 5 (25%), p = 0.002) and the success rate (95% (19) and 60% (12), p = 0.008) were higher in the ultrasound group. The number of cannulas used in the ultrasound group was less than the palpation group (p = 0.001). The cost of intervention was higher in the palpation group compared to the ultrasound group (p = 0.048). CONCLUSIONS: The ultrasound-guided cannulation of the femoral artery in neonates is superior to the palpation technique based on the increased of the number of successful first-attempt cannulation and success rate, and the reducing of the access time, number of attempts, number of cannulas used, and cost of cannulation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cateterismo Periférico , Recém-Nascido , Humanos , Artéria Femoral/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Estudos Prospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Palpação/métodos , Artéria Radial/diagnóstico por imagem
10.
Avian Pathol ; 52(1): 78-83, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36415970

RESUMO

The aim of this study was to estimate the sensitivity and specificity of palpation relative to necropsy for detection of keel bone fractures (KBF) in broiler breeders. In addition, the study investigated observer reliability of palpation. Four commercial breeder flocks (Ross 308 n = 2, Ranger Gold n = 1, Hubbard JA 757, n = 1) were included in the study. A total of 400 hens and 60 roosters were examined after culling or slaughter, at end of lay (63 weeks). Keel bones were first palpated independently by two raters with a varying degree of experience in palpation of keel bones in laying hens. After palpation, a necropsy with investigation of the keel bone was conducted. The prevalence of KBF at end of lay for hens, as diagnosed by necropsy, varied from 14-58%, while only one in 60 assessed roosters had KBF. Palpation had poor sensitivity, with differences between raters ranging from 56% to 36% when hybrid is not considered. The specificity of palpation for all hybrids together was 85% and 88%, for the two raters, respectively. The two raters had moderate agreement, Gwet's agreement coefficient (95% confidence interval): 0.60 (0.52-0.69). In conclusion, palpation has poor diagnostic accuracy for detection of KBF in broiler breeders, and other methods, like necropsy, must be applied for reliable assessments. KBF appears to be a prevalent condition in different hybrids of broiler breeder hens, but not in roosters.RESEARCH HIGHLIGHTS This is the first study to investigate palpation as a diagnostic method for detection of KBF in broiler breeders.Palpation has poor diagnostic accuracy for detection of KBF in broiler breeder hens with differences between raters.KBF can be a prevalent problem in broiler breeder hens of several hybrids, but not in roosters.


Assuntos
Galinhas , Fraturas Ósseas , Animais , Feminino , Masculino , Reprodutibilidade dos Testes , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/veterinária , Palpação/veterinária , Palpação/métodos , Esterno
11.
J Complement Integr Med ; 20(2): 431-437, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36351325

RESUMO

OBJECTIVES: The primary aim of the study is to explore the knowledge and use of palpatory tests in detecting somatic dysfunction, the second is to assess the knowledge about the inhibitory tests among osteopathic practitioners in Italy, England, and France. METHODS: A quantitative survey was conducted, between March and May 2021, through the administration of a semi-structured questionnaire. The participants had to answer 8 questions. RESULTS: A total of 2,223 e-mails were sent: 423 manual therapy professionals participated in the survey. Subsequently, only the responses of the 385 osteopaths (280 Italian, 23 French and 82 British) were included in the data processing; the 38 excluded were physiotherapists and chiropractors. The most significative outcomes for the total sample were found to: years of working experience and knowledge of a palpatory test that allows to discriminate two dysfunctional anatomical structures was significant with a χ2=12.509 (p-value <0.006); 68.5% answered in the affirmative to this last question. It was found that less work experience is associated with knowledge of a palpatory test to discriminate two dysfunctional structures. The correlation between years of work experience and knowledge of the inhibitory test was explored with the result being statistically significant (p-value <0.001). 64.4% know and use the inhibitory test. 39.1% base the inhibitory test on tissue change. CONCLUSIONS: The clinical practice of Italian and French professionals, makes possible to establish the hierarchy between two somatic dysfunctions with respect to English sample. The osteopaths reported a wider use of the tissue change parameters rather than pain reported by the patient. Furthermore, more than half of the sample-based their discriminatory test on the musculoskeletal and fascial systems. There is a vast knowledge of the inhibition test among osteopaths.


Assuntos
Manipulações Musculoesqueléticas , Medicina Osteopática , Médicos Osteopáticos , Humanos , Palpação/métodos , Inquéritos e Questionários
12.
Sci Rep ; 12(1): 21374, 2022 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-36494492

RESUMO

Palpation is widely used as the initial medical diagnosis. Integration of micro tactile sensors and artificial muscles enables a soft microfinger for active touch sensing using its bending actuation. Active touch sensing by pushing-in motion of microfinger enables to evaluate stiffness distribution on an elastic object. Due to its compactness, the microfinger can enter a narrow space, such as gastrointestinal and abdominal spaces in a body. However, a microfinger can only touch and sense limited points. We aim at efficient method for searching a stiffness singular part in an elastic object by the directional touch sensing of a microfinger. This study presents a microfinger for active touch sensing using bending and push-in actuation and proposes an algorithm utilizing directivity in touch sensing by a microfinger for efficient localization of the stiffness singular part in an object. A gelatin block structure with a small rigid ball was prepared and touch sensed by the microfinger. Consequently, the position of the buried rigid ball could be efficiently identified based on the proposed algorithm. This result implies that the proposed method has potential applications in endoscopic medical diagnosis, particularly in identifying tumor positions.


Assuntos
Percepção do Tato , Tato , Palpação/métodos , Endoscopia , Algoritmos
13.
Ann Card Anaesth ; 25(4): 447-452, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36254909

RESUMO

Background: Ultrasound-guided (USG) radial artery cannulation against the standard palpation technique increases the first attempt rate in both pediatric and adult patients. The objective of this study was to evaluate the benefits of USG versus the palpation technique in improving the first attempt rate in elderly patients. Methods: The patients over 65 years of age were randomized to the USG or Palpation group. The radial artery identification in the USG group was performed with the aid of the Sonimage HS 1. In the Palpation group, the radial artery was identified by manual palpation. The operators were cardiothoracic anesthesiologists. Overall success was defined as cannulation completed within 10 min. Results: Eighty patients (40 in each group) were recruited. The respective first attempt and overall success rate for the USG group were similar to the Palpation group (P > 0.999 and P = 0.732). The time to the first attempt and overall success were also similar (P = 0.075 and P = 0.636). The number of attempts, number of catheters used, and failure rates were similar between the groups (P = 0.935, P = 0.938, and P = 0.723). The number of successful cannulations within 10 min was similar for both the groups as categorized by the radial artery diameter (P = 0.169). Conclusions: The USG did not increase the first attempt or overall success rate of radial artery cannulation in the elderly patients undergoing cardiothoracic surgery. The time to first attempt and overall success were similar between both the groups. The number of attempts and number of catheters used were similar between both groups.


Assuntos
Cateterismo Periférico , Artéria Radial , Adulto , Idoso , Cateterismo Periférico/métodos , Criança , Humanos , Palpação/métodos , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Ultrassonografia de Intervenção/métodos
14.
Vet Anaesth Analg ; 49(6): 589-596, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36175294

RESUMO

OBJECTIVES: To record the success rate of veterinary professionals and students at identifying the pulse in conscious and anaesthetized dogs. To explore the influence of clinical experience, pulse location, anaesthesia and likely confounding variables on the success of pulse palpation. STUDY DESIGN: Prospective, observational, randomized study. ANIMALS: A total of 54 client-owned dogs scheduled for general anaesthesia. METHODS: For each dog, three participants (senior anaesthetist, anaesthesia resident/nurse, veterinary student/animal care assistant) attempted pulse palpation at three locations (femoral, radial and dorsal pedal pulse) in conscious and anaesthetized dogs. The time to pulse palpation was measured with a stopwatch for each attempt and data were modelled using a multivariate Cox regression survival analysis (significance p < 0.05). RESULTS: The overall success rate of pulse palpation was 77%, with a median time of 10.91 seconds (interquartile range 9.09 seconds). Success rate was lower in conscious dogs (67%) than in anaesthetized dogs (87%). There was a 77% lower likelihood of success at the radial than at the femoral pulse [hazard ratio (HR) 0.23, 95% confidence interval (CI) 0.38-0.69, p < 0.001]. Veterinary students/animal care assistants had a 71% lower likelihood of success than senior anaesthetists (HR 0.29, 95% CI 0.22-0.39, p < 0.001). Age, weight and American Society of Anesthesiologists physical status had no significant influence. Premedication/anaesthetic drugs, heart rate or mean arterial pressure had no significant influence on the time to pulse palpation in anaesthetized dogs. The median time to palpation was less than 10 seconds for all experience groups at the femoral location. CONCLUSIONS: Palpation of the femoral location had the greatest likelihood of success with the least amount of time. Monitoring the femoral pulse during induction of anaesthesia is suggested as a method for confirming spontaneous circulation. Pulse palpation improves with clinical experience.


Assuntos
Anestésicos , Palpação , Cães , Animais , Frequência Cardíaca , Estudos Prospectivos , Palpação/métodos , Palpação/veterinária , Anestesia Geral/veterinária , Anestésicos/farmacologia
15.
J Manipulative Physiol Ther ; 45(5): 337-345, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-36175313

RESUMO

OBJECTIVE: The purpose of this study was to examine the accuracy of palpation methods for locating the transverse processes of the first cervical vertebra and masseter muscle using radiographic images as the gold-standard method and the association between personal characteristics with the observed accuracy. METHODS: This was a single-blinded, diagnostic accuracy study. Ninety-five participants (49 women, 58 ± 16 years of age) were enrolled in this study. A single examiner palpated the neck and face region of all participants to identify the transverse processes of the first cervical vertebra and masseter muscles bilaterally. In sequence, participants underwent a multislice computed tomography scan for assessment of the superimposed inner body structure. Two radiologists assessed the computed tomography images using the same criteria and were blinded regarding each other's assessment and the anatomic landmarks under investigation. The palpation accuracy was calculated as the proportion of the correctly identified landmarks in the studied sample. The correlation of the palpation outcome (correct = 1; incorrect = 0) with age, sex (male = 1; female = 0), and body mass index was investigated using the point-biserial correlation coefficient. RESULTS: The right and left transverse processes were correctly located in 76 (80%) and 81 (85%) participants, respectively, and bilaterally in 157 events (83%), as evaluated by the consensus of the 2 radiologists. The masseter muscles were correctly localized bilaterally in 95 of 95 (100%) participants. Body mass showed statistical evidence of a weak, positive correlation with the correct location of the transverse processes of the first cervical vertebra at the right body side (r = .219; 95% confidence interval, 0.018-0.403; P = .033). CONCLUSION: Palpation methods used in this study accurately identified the location of the first cervical vertebra spinous processes and the masseter muscles.


Assuntos
Músculo Masseter , Palpação , Humanos , Masculino , Feminino , Músculo Masseter/diagnóstico por imagem , Palpação/métodos , Pescoço , Tomografia Computadorizada por Raios X , Índice de Massa Corporal
16.
Can J Anaesth ; 69(10): 1211-1219, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35941333

RESUMO

PURPOSE: Using machine learning, we developed a proprietary ultrasound software called the Spine Level Identification (SLIDE) system, which automatically identifies lumbar landmarks in real time as the operator slides the transducer over the lumber spine. Here, we assessed the agreement between SLIDE and manual palpation and traditional lumbar ultrasound (LUS) for determining the primary target L3-4 interspace. METHODS: Upon institutional ethics approval and informed consent, 76 healthy term parturients scheduled for elective Caesarean delivery were recruited. The L3-4 interspace was identified by manual palpation and then by the SLIDE method. The reference standard was located using traditional LUS by an experienced operator. The primary outcome was the L3-4 interspace identification agreement of manual palpation and SLIDE with the reference standard, as percentage agreement and Gwet's agreement coefficient (AC1). RESULTS: The raw agreement was 70% with Gwet's agreement coefficient (AC1) = 0.59 (95% confidence interval [CI], 0.41 to 0.77) for manual palpation and 84% with Gwet's AC1 = 0.82 (95% CI, 0.70 to 0.93) for SLIDE. When the levels differ from the reference, the manual palpation method identified L2-3 more often than L4-5 while the SLIDE method identified equally above or below L3-4. The SLIDE system had greater agreement than palpation in locating L3-4 and all other lumber interspaces after controlling for body mass index (adjusted odds ratio, 2.99; 95% CI, 1.21 to 8.7; P = 0.02). CONCLUSION: The SLIDE system had higher agreement with traditional ultrasound than manual palpation did in identifying L3-4 and all other lumber interspaces after adjusting for BMI in healthy term obstetric patients. Future studies should examine factors that affect agreement and ways to improve SLIDE for clinical integration. STUDY REGISTRATION: www. CLINICALTRIALS: gov (NCT02982317); registered 5 December 2016.


RéSUMé: OBJECTIF: À l'aide de l'apprentissage automatique, nous avons développé un logiciel d'échographie propriétaire appelé SLIDE (pour Spine Level Identification, c.-à-d. système d'identification du niveau vertébral), qui identifie automatiquement les points de repère lombaires en temps réel lorsque l'opérateur fait passer le transducteur sur la colonne lombaire. Ici, nous avons évalué l'agrément entre le SLIDE et la palpation manuelle et l'échographie lombaire traditionnelle pour déterminer l'espace intervertébral cible principal L3­L4. MéTHODE: Après avoir obtenu l'approbation du comité d'éthique de l'établissement et le consentement éclairé, 76 parturientes en bonne santé et à terme devant bénéficier d'un accouchement par césarienne programmée ont été recrutées. L'espace intervertébral L3­L4 a été identifié par palpation manuelle puis avec le logiciel SLIDE. L'étalon de référence a été localisé à l'aide d'une échographie lombaire traditionnelle par un opérateur expérimenté. Le critère d'évaluation principal était l'agrément entre l'identification de l'espace intervertébral L3­L4 par palpation manuelle et par logiciel SLIDE avec l'étalon de référence, en pourcentage d'agrément et coefficient d'agrément de Gwet (CA1). RéSULTATS: L'agrément brut était de 70 % avec le coefficient d'agrément de Gwet (CA1) = 0,59 (intervalle de confiance [IC] à 95 %, 0,41 à 0,77) pour la palpation manuelle et de 84 % avec le CA1 de Gwet = 0,82 (IC 95 %, 0,70 à 0,93) pour le logiciel SLIDE. Lorsque les niveaux lombaires différaient de la référence, la méthode de palpation manuelle a identifié L2­L3 plus souvent que L4­L5, tandis que la méthode SLIDE a identifié les vertèbres supérieures ou inférieures à L3­L4 de manière égale. Le système SLIDE a affiché un agrément plus important que la palpation pour localiser L3­L4 et tous les autres espaces intervertébraux lombaires après ajustement pour tenir compte de l'indice de masse corporelle (rapport de cotes ajusté, 2,99; IC 95 %, 1,21 à 8,7; P = 0,02). CONCLUSION: Le système SLIDE avait affiché un agrément plus élevé avec l'échographie traditionnelle que la palpation manuelle pour identifier le niveau L3­L4 et tous les autres espaces intervertébraux lombaires après ajustement pour tenir compte de l'IMC chez les patientes obstétricales à terme en bonne santé. Une étude future devrait examiner les facteurs qui affectent l'agrément et les moyens d'améliorer le logiciel SLIDE pour une intégration clinique. ENREGISTREMENT DE L'éTUDE: www.clinicaltrials.gov (NCT02982317); enregistrée le 5 décembre 2016.


Assuntos
Região Lombossacral , Palpação , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Palpação/métodos , Gravidez , Software , Coluna Vertebral , Ultrassonografia
17.
Pediatr Emerg Care ; 38(9): e1533-e1537, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36040472

RESUMO

BACKGROUND: The cricothyroid membrane (CTM) is the most important anatomic structure when performing emergency front-of-neck access (FONA) procedures. Adolescence is a period of rapid morphologic change in laryngeal structures, including the CTM. We hypothesized that the adolescent CTM would be sufficiently different from pediatric or adult anatomy to merit special consideration in FONA. OBJECTIVE: The aim of the study was to define the procedurally relevant CTM anatomy in an adolescent population. METHODS: This was a retrospective, multicenter cohort study composed of patients who underwent a diagnostic computed tomography scan during routine clinical care. Inclusion criteria were ages 16 to 19 years and a computed tomography of the neck with or without contrast. The primary outcome was CTM height measured in the midsagittal plane using electronic calipers. RESULTS: One hundred thirty-four imaging studies met inclusion criteria. The average CTM height was strongly associated with age and ranged between 5.4 and 6.2 mm in male adolescents and 4.6 and 5.8 mm in female adolescents. We predicted that standard cuffed endotracheal and tracheostomy tubes recommended for FONA procedures (5.0- and 6.0-mm devices) could potentially fail for most patients in our cohort. CONCLUSIONS: The adolescent CTM is smaller than previously recognized. We recommend having a variety of equipment sizes readily available at any site where airway management in adolescents may occur.


Assuntos
Cartilagem Cricoide , Palpação , Adolescente , Adulto , Criança , Estudos de Coortes , Cartilagem Cricoide/anatomia & histologia , Cartilagem Cricoide/diagnóstico por imagem , Feminino , Humanos , Masculino , Palpação/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
18.
J Manipulative Physiol Ther ; 45(3): 227-234, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35879125

RESUMO

OBJECTIVE: The purpose of this study was to determine the accuracy and intrarater reliability of a palpatory protocol based on a combination of 3 palpatory methods to identify both the C7 spinous process (C7 SP) and the factors that affect the errors and inaccuracy of palpation. METHODS: Twenty-five women between the ages of 18 and 60 years were submitted to a palpation protocol of the C7 SP, and a radiopaque marker was fixed on the skin at the possible location of the vertebrae. A radiograph and a photograph of the cervical spine were obtained in the same posture by a first rater. A second rater performed the same palpation protocol and took a second photograph. The accuracy and measurement error of the palpation protocol of C7 SP were assessed through radiographic images. The inter-rater reliability was estimated by the interclass correlation coefficient and assessed using photographs of each rater. The Pearson's correlation coefficients (r), the Fisher exact test, and the χ2 test were used to identify the factors associated with the error and inaccuracy of palpation. RESULTS: Accuracy of the C7 palpation was 76% with excellent reliability (interclass correlation coefficient = 0.99). There was a moderate correlation between weight and the measurement of palpation error (r = -0.6; P = .003). One hundred percent of inaccuracy palpation was related to the increased soft-tissue thickness (P = .005) in the cervical region. CONCLUSION: The palpation protocol described in this study was accurate and presented excellent reliability in identifying the C7 SP. Increased weight and dorsocervical fat pad were associated to error and palpation inaccuracy, respectively.


Assuntos
Vértebras Cervicais , Palpação , Adolescente , Adulto , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Palpação/métodos , Postura , Reprodutibilidade dos Testes , Adulto Jovem
19.
BMC Endocr Disord ; 22(1): 181, 2022 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-35843955

RESUMO

Thyroid nodule is a common health problem in endocrinology. Thyroid fine-needle aspiration biopsy (FNAB) cytology performed by palpation guided FNAB (PGFNAB) and ultrasound-guided FNAB (USGFNAB) are the preferred examinations for the diagnosis of thyroid cancer and part of the integration of the current thyroid nodule assessment. Although studies have shown USGFNAB to be more accurate than PGFNAB, inconsistencies from several studies and clinical guidelines still exist.The purpose of this study is to compare the diagnostic accuracy of Palpation versus Ultrasound-Guided Fine Needle Aspiration Biopsy in diagnosing malignancy of thyroid nodules.The systematic review and meta-analysis were prepared based on the PRISMA standards. Literature searches were carried out on three online databases (Pubmed/MEDLINE, Embase, and Proquest) and grey literatures. Data extraction was carried out manually from various studies that met the eligibility, followed by analysis to obtain pooled data on sensitivity, specificity, Diagnostic Odds Ratio (DOR) and Area Under Curve (AUC), and the comparison of the two methods.Total of 2517 articles were obtained, with 11 studies were included in this systematic review. The total sample was 2382, including 1128 subjects using PGFNAB and 1254 subjects using USGFNAB. The risk of bias was assessed using QUADAS-2 with mild-moderate results. The results of sensitivity, specificity, AUC and DOR in diagnosing thyroid nodules using PGFNAB were 76% (95% CI, 49-89%), 77% (95% CI, 56-95%), 0.827 and 11.6 (95% CI, 6-21) respectively. The results of sensitivity, specificity, AUC and DOR in diagnosing thyroid nodules using USGFNAB were 90% (95% CI, 81-95%), 80% (95% CI, 66-89%), 0.92 and 40 (95% CI, 23-69), respectively the results of the comparison test between PGFNAB and USGFNAB; Tsens USGFNAB of 0.99 (p = 0.023), AUC difference test of 0.093 (p = 0.000023).The diagnostic accuracy of USGFNAB is higher than PGFNAB in diagnosing malignancy of thyroid nodules. If it is accessible, the author recommends using USGFNAB as a diagnostic tool for thyroid nodules.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Biópsia por Agulha Fina/métodos , Humanos , Palpação/métodos , Sensibilidade e Especificidade , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia de Intervenção
20.
Respir Care ; 67(9): 1154-1160, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35820703

RESUMO

BACKGROUND: Arterial cannulation is an important procedure for hemodynamic monitoring and blood sampling. Traditional radial artery cannulation is performed by using anatomical knowledge and pulse palpation as a guide. Arterial cannulation using ultrasound (US) requires specific training, especially for new US users. We hypothesized that even for new US users, US guidance would facilitate the successful puncture by lower attempts before successful intraluminal cannulation of a simulation model of the radial artery. METHODS: A prospective randomized controlled crossover study was conducted with new US users on a gelatin phantom wrist. Three sessions of training were proposed: US-guided technique with low blood pressure (BP), palpation-guided technique with high BP, and one secondary comparison with low BP. For the 2 first sessions, all volunteers performed each technique but not in the same order. The main criterion was the number of attempts before successful catheterization of the model artery. A secondary criterion was the number of needle movements (the number of attempts plus the number of needle directional changes). RESULTS: Twenty new US users participated in the study. Numbers of attempts before successful catheterization were significantly lower when using the US technique: 1.1 (± 0.4) for US versus 1.6 (± 0.8) for palpation high BP (P = .02) versus 2.5 (± 1.4) for the secondary comparison, palpation low BP (P < .001). All of the participants achieved success after the 12th needle movement for US technique, after the 19th needle movement for palpation high BP, and after the 25th needle movement for the secondary comparison, palpation low BP. The total time before success was not significantly different between the 2 first sequences (US vs palpation high BP). CONCLUSIONS: US technique was more successful than traditional palpation technique for novice US users performing arterial cannulations for the first time. A study in the clinical practice is needed to confirm these results.


Assuntos
Cateterismo Periférico , Hipotensão , Treinamento por Simulação , Cateterismo Periférico/métodos , Estudos Cross-Over , Humanos , Palpação/métodos , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...